You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
Home > Inverter Support > IC Series Inverter/Charger Support > IC 2000 & 3000 Support > IC Series Inverter/Charger: AC TERMINAL BLOCK CONNECTIONS
IC Series Inverter/Charger: AC TERMINAL BLOCK CONNECTIONS
print icon

AC TERMINAL BLOCK CONNECTIONS 

 

 

The IC Series has a six-pole AC terminal block and two AC ground terminals to connect the Inverter/Charger’s AC input and output wiring.

The terminal block and ground terminals can be accessed by removing the three Phillips screws holding the AC cover plate.

Each connection on the AC terminal block is rated to accept one #14 to #6 AWG CU stranded wire, or two #12 AWG CU stranded wires. Use a flathead screwdriver to release and tighten the set screws.

The AC ground terminals can accept two #14 to #6 AWG CU stranded wire. Use a flathead screwdriver to release and tighten the set screws.

The IC Series’ ACN-IN and ACN-OUT terminals are electrically isolated from each other when in “inverting mode”, which helps to prevent ground-loops. If the installation requires the AC Input and AC Output neutrals to be connected together, the Inverter/Charger’s neutral-to-ground connection must be disconnected (See section 3.6.11).