You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
This article preview will expire in 30 minutes, after which it will no longer be accessible.
Home > Battery Support > DuraCUBE Portable Power Station Support > DURALITE 100-WATT PORTABLE SOLAR KIT: BATTERY CHARGING PROFILE CHART
DURALITE 100-WATT PORTABLE SOLAR KIT: BATTERY CHARGING PROFILE CHART
print icon
ITEM  SEALED  GEL  FLOODED   LF1(12V) LF2  (24V)
Over Voltage Disconnect Voltage 16.0V 16.0V 16.0V 14.6V 29.2V
Charging Limit Voltage 15.0V 15.0V 15.0V 14.8V 28.8V
Over Voltage Reconnect Voltage 15.0V 15.0V 15.0V 14.8V 28.8V
Equalize Charging Voltage 14.6V ------ 14.8V ------ ------
Boost Charging Voltage 14.4V 14.2V 14.6V 14.8V 28.8V
Float Charging Voltage 13.8V 13.8V 13.8V 14.0V 28.0V
Boost Reconnect Charging Voltage 13.2V 13.2V 13.2V 13.2V 26.4V
Low Voltage Reconnect Voltage  12.6V 12.6V 12.6V 12.2V 24.4V
Under Voltage Warning Reconnect Voltage 12.2V 12.2V 12.2V 12.4V 28.8V
Under Voltage Warning Voltage 12.0V 12.0V 12.0V 12.0V 24.0V
Low Voltage Disconnect Voltage 11.1V 11.1V 11.1V 11.0V 22.0
Discharging Limit Voltage 10.6V 10.6V 10.6V 10.5V 21.0V
Equalize Duration 120min. ------ 120min. ------ ------
Boost Duration 120min. 120min. 120min. 120min. 120min.

 

1. When the battery type is sealed, gel, flooded, the adjusting range of equalizing duration is 0 to180min and boost duration is 10 to180min.

 

2. When setting a custom “User” battery type, (for example: a LiFePO4) use these rules when setting voltage parameters. Note LFP1 is used for 12V Lithium batteries.

 

LFP2 is used for 24V lithium batteries and should not be used for the DuraLite kit.

 

 

 

• Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage.

• Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage

• Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit Voltage.

• Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥ Discharging Limit Voltage.

• Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.

Feedback
0 out of 0 found this helpful

scroll to top icon