IC-3000-12-PKG / IC-2000-12-PKG / Inverter Charger/ Overview : Error Codes
List of Error Codes
Below are two tables that identify inverter error codes, and how to remedy them. 
| Remote Error Codes | ||
| PTOC (Over current protection) | Pulling to much current from inverter | Turn off loads, unplug from shore power, power cycle the inverter. Turn inverter back on and re-apply shore power | 
| OTP (Over Temperature Protection) | Inverter or batteries are to hot | Check battery connections. Is battery to hot? Remove temp sensor | 
| UTP (under temperature Protection) | Inverter or batteries are to cold | Warm batteries up in some way | 
| UVP (Under voltage protection) | Battery voltage is below Low voltage disconnect point on the inverter | Recharge batteries above LVD set on inverter. Then turn inverter on and re-apply shore power | 
| OOCP (Over current protection) | Second over current message | Turn off loads, unplug from shore power, power cycle the inverter. Turn inverter back on and re-apply shore power | 
| OVP (Over voltage protection) | Battery volatge is to high | Unplug shore power power cycle the inverter. Run inverter without shore power to drop battery voltage. Check charge settings on all sources | 
| Poff (NO ac power) | NO AC input power | Check breakers and AC getting to inverter | 
| OLP Over Load protection | Loads to high for inverter output | Turn off loads, unplug from shore power, power cycle the inverter. Turn inverter back on and re-apply shore power. Turn loads on one by one eliminating load causing the issue | 
| Error Beeps From Inverter | |
| Beeping counts | Protection signal | 
| 1 beep | UTP (Under Temp Protection) | 
| 2 beep | OTP (Over Temp Protection) | 
| 3 beep | OVP | 
| 4 beep | UVP | 
| 5 beep | Short-circuit or OLP | 