Jun 24, 2022
2241
POWER SHARING MODE
In power sharing mode:
- The power required by the appliances (fridge, TV, charger) is 4200W (35AAC x 120VAC) - 1.
- Shore power (Utility or Generator) is connected and supplying 6000W (50AAC x 120VAC) - 2.
- 4200W of AC power is passed through OUT 1 on the Inverter/Charger to power the appliances - 3.
- The remaining AC Power: 1800W (15AAC x 120VAC) is used for battery bank charging, up to 100 Amps (with the 2000W) or 125 AMPs (with the 3000W) DC per hour - 4.